Undertun motion compensated gangways has been developed to provide safe and cost-effective offshore access solution for personnel or crew transfer from vessels to oil and gas platforms, offshore wind turbine, ship-to-ship and more.
Our compact and light weight gangways ensure simple installation. Ship supply of electric power makes installation quick, redundant power can be set up from the vessel system.
Available with both active roller end for landing on flat platforms or decks and alternatively with a gripper end which grips standard boat landings or stanchions.
Class Approval | DNVGL ST-358 |
Weight | 4350 kg |
Maximum Reach (from hinge) | 15 m + end gripper/roller |
Maximum Internal Width | 620 mm |
Compensation Envelope | |
HPU Power | 3 x 440 VAC 22 kW nom |
Emergency Power | 2 x 230 VAC 500 W nom (battery) |
Oil Tank in HPU | 90 liters |
Class Approval | DNVGL ISO-7061 |
Weight | 2550 kg |
Maximum Reach (from hinge) | 12 m + end gripper/roller |
Maximum Internal Width | 620 mm |
Compensation Envelope | |
HPU Power | 3 x 230 VAC 22 kW nom |
Emergency Power | 2 x 230 VAC 500 W nom (battery) |
Oil Tank in HPU | 90 liters |